This requires clinical mastery, a human connection between the surgeon and the. The current main techniques of posterior lumbar interbody fusion plif surgery all incorporate a supplementary intervertebral implant. Ease of cage insertion placement of cage with minimal exposure needed. Impacted cages made of titanium, carbonfiber reinforced or plain peek polymer polyetheretheketone. Trabecular metal acetabular revision system cupcage construct prepare the acetabulum. Surgical options include the use of a protrusio cage with a tha. Anatomical reconstruction using the anatomical shouldersystem allows the potential for the surgeon to restore the geometry of a. In addition, with the use of locking caps the screws can be locked and made angularly stable. Please select a location and click search to find an associate near you. The cage requires more extensive exposure from the ilium to the ischium. Lumbar interbody fusion indications techniques and. Zimmer biomet launches avenue t tlif cage spinal news. Cage system along with the general instruments designed specifically for its placement. Zimmer biomet launchs new cage with vertebridge plating.
Surgical technique for smartcages orthopaedic innovation. Acetabular revision in total hip arthroplasty with tantalum. One gram of cefazolin and, if a urinary catheter was inserted, an appropriate dose of gentamicin was given at induction of anesthesia. Avenue t tlif cage surgical technique guide zimmer biomet. Indications united states the roia implant system is indicated for intervertebral body fusion of the lumbar spine, from l2 to s1, in skeletally mature patients who have had six months of nonoperative treatment.
Clinical and radiological outcomes of minimally invasive versus open transforaminal lumbar interbody fusion. The burchschneider cage allows weight bearing on the affected joint soon after the operation. As the company wrote in its news release, avenue t advances posterior lumbar cage technology by incorporating vertebridge plating, which facilitates simplified cage insertion and zeroprofile, intradiscal fixation through a direct, minimally invasive surgical mis approach. Provides great detail on the basics of surgery that allow you to build your craft. Introduction spinal fusion the ultimate goal of a fusion is the elimination of pathologic segmental motion and its accompanying symptoms achieved by the formation of osseous bridging across the previously mobile level. Titanium cages in the surgical treatment of severe vertebral osteomyelitis. The survivorship of protrusio cages for metastatic disease involving. Everyday low prices and free delivery on eligible orders. This will continue to be a good reference for general surgeons both during and after training. The surgical technique for an ilioischial cage reconstruction used by the senior author has previously beendescribed. Conventus cage ph surgical techniques conventus orthopaedics the conventus cage ph ph cage is a permanent implant comprised of an expandable scaffold, made from nitinol and titanium, which is deployed into the medullary canal and provides a structure to which bone fragments are attached using fragment screws. This is the fourth edition of a compact, classic book on the essentials of surgical technique and anatomy, just as the title states.
Four 3mm pmma spacers, strategically positioned in loadbearing areas, help centralize the cup and create a. Zimmer nexgen complete knee solution lps surgical technique 5 micromill hand piece assembly and usage 1. Cervical corpectomy cage provides enhanced stability. Cableready greater trochanteric reattachment surgical technique 3 fig. My personal thoughts are included to reflect my clinical practice and operative techniques.
Roic cervical cage surgical technique guide 3 zimmer biomet spine does not practice medicine. This booklet can be ordered through zimmer, reference catalog number 97522400300. Whether or not all cable locations are utilized, all set screws should be locked down at the completion of the procedure. The following general surgical technique guide is for illustrative purposes only. In this case, we used a standard deltopectoral surgical approach to reduce and fix the fracture using the ph cage. Select the zca cup outside diameter that matches the size of the last acetabular reamer used. It discusses the procedure for component sizing, bone preparation, trial reduction, cementing techniques. The clavicle plates are low profile, precontoured, stainless steel central third and distal plates that combine locking and nonlocking options in each plate. Zuk is a clinically proven uni knee replacement introduced globally in 2004. Zero pva surgicaltechnique depuysynthes 1 table of contents introduction surgical technique product information bibliography zerop va 2 ao principles 4 indications and contraindications 5 preparation 6 considerations for use adjacent to prior fusion 7 patient positioning, exposure and disectomy 8 implant insertion 10 screw fixation 15 option a. The acetabular cups were the charnley lpw for charnley stems, the zca for zimmer.
Class 2 device recall zimmer trabecular metal reverse. This technique was developed in conjunction with health care professionals. It is a very good, quick reference for common general surgical procedures. Use ball impactors andor reverse reaming to impact the bone graft. The most likely mechanism of failure in the followup period for any interbody fusion is either pseudarthrosis or displacement of the. Surgical management of a long segmental defect of the humerus using a cylindrical titanium mesh cage and plates. Acetabular revision surgery is a complex procedure that may present several. Identify the margins of the acetabulum using blunt and sharp hohmanntype retractors or similar. Clavicle plate and screw system the clavicle plate and screw system is a comprehensive set of plates, screws and instrumentation designed to treat central third and distal clavicle fractures.
Pdf titanium cages in the surgical treatment of severe. Orthopedic manual surgical instrument product code lxh. The invizia system provides several options for screw hole preparation, including. The amount of press fit used should be determined at the time of surgery and be based upon bone quality. Zca allpoly cups can be used in primary or revision surgery and with zca reconstruction roof rings or cages. Each surgeon should exercise his or her own independent judgment in the diagnosis. Zimmer surgical technique guide charlotte shoulder.
The zimmer trabecular metal reverse shoulder system is a treatment option for patients with severe rotator cuff rc deficiency. The zca snapin cup helps reduce the risk of dislocation with. Zimmer biomet has officially launched the avenue t transforaminal lumbar interbody fusion tlif cage in the usa. The zimmer revision knee arthroplasty surgical guidelines booklet is recommended for a more complete discussion on revision total knee arthroplasty technique. The science and art of medical care is to provide the right. The nuvasive xcore mini cervical expandable vbr system is indicated for use in the cervical spine area c3c7 vertebral bodies in skeletally mature patients in order to replace a diseased or damaged vertebral body caused by tumor, fracture, or osteomyelitis. This is by far the best surgical book and along with ohcm the best text book ever written. Assemble the selected zca allpoly cup on the alignment guide and insert the cup into the previously placed bone cement fig. The cup should be seated in approximately 45 degrees of abduction and 20 degrees of forward flexion independent of roof ring or cage orientation. Zca allpoly acetabular cup surgical technique all poly. Only those individuals with specialized training and experience in spinal surgery should attempt to use the. Tricor sacroiliac joint fusion system open technique open technique hcp content posted august 20, 2014 in zimmer biomet spine and animated demonstrations. This document is intended for surgeons and is not intended for laypersons. Allpoly cups can be used in primary or revision surgery, and with zca reconstruction roof rings or cages.
As with all surgical procedures, the technique used in each case will depend on the surgeons medical judgment as to the best treatment for each patient. Over 1 million times per year, biomet helps one surgeon. With the air hose detached, disengage the shield lock and retract the shieldplunge guide to expose the collet. Cableready greater trochanteric reattachment zimmer. For example, if a 54mm reamer was used, choose a 53mm od cup. Subsequently, the acetabular component zca zimmer biomet holding, inc. Identify the hip center and use the acetabular reamers to size and shape the acetabulum for the. Expandable cage technology foundation for orthopaedic. The cage allows the relatively simple and stable repair of bony defects in the acetabulum. A traditional transverse trochanteric osteotomy may be necessary, but a trochanteric slide may also be adequate. The quantitative analysis of tissue injury markers after miniopen lumbar fusion. The technique described is consistent with recent literature supporting the use of the ph cage for fracture fixation. To position the second cage, repeat steps one to seven. Surgical technique surgical approach the roof ring may be implanted using any conventional approach since all provide adequate exposure.
It involves placing an interbody cage in an oblique direction and a strong pedicle screw posterior construct that temporarily stabilizes the spine until bony fusion takes place via sentinel and interbody bone. Avoid reverse or repeated bending of the titanium implant as. This guide to the surgical technique is a stepbystep procedure written for medial compartment uka using the most widely adopted of the three techniques, the spacer block. Patients consents were taken for the procedure, including the use of allograft bone. Insert the cutter onto the mill until it is fully seated fig. The implant eliminates the need for a second procedure to insert pins. Avenue t tlif cagesurgical technique guide 3 zimmer biomet spine does not practice medicine. Csti porous coating provides potential for optimal ingrowth fixation.
Fixation of a proximal humeral fracture using a novel. The patient was then placed in the lateral position on the operating table and a prescrub. Zca allpoly acetabular cup 4 1 acetabular preparation ensure that the rim of the acetabulum is fully exposed. Trabecular metal acetabular revision system cupcage. Promising midterm results with a cupcage construct for large. This technique details the placement of the ltcage lumbar tapered fusion device through an open, anterior technique. As with any surgical technique, failures are bound to occur. Tlif surgical technique step one with the patient supine, a cutaneous incision, parallel to the sagittal plane, is performed on the affected area, about 4 to 4. Transforaminal lumbar interbody fusion tlif is performed for conditions, including spinal stenosis, degenerative scoliosis, and spondylolisthesis of the lumbar spine. Expandable tlif and plif technology surgical technique. In addition to the surgical steps, this technique highlights the key features of the lumbar tapered instruments. The cage design also allowsfor unconstrained positioningof for tuberosity fixation. The epub format uses ebook readers, which have several ease of reading.
The reconstruction of periprosthetic pelvic discontinuity. The subsequent reconstruction involved either an ilioischial cage zca or burchschneider. Threaded cylindrical cages made of titanium, cortical allograft donor bone or synthetic bone. Zimmer gmbh sulzer allee 8 winterthur switzerland for additional information contact.
The burchschneider cage has thus become a classic acetabular implant, which has been copied many times. The cage design also allows for unconstrained positioning of screws for tuberosity fixation. If the last reamer used was an even dimension, choose the cup size that is 1mm less than the last reamer used. Lumbar interbody fusion indications, techniques, and complications dr praveen k tripathi 27jan16 1 2. Zimmer periarticular proximal humeral locking plate surgical technique introduction the zimmer periarticular locking plate system combines locking screw technology with periarticular plates to create fixedangle constructs for use in comminuted fractures or where deficient bone stock or poor bone quality is encountered. This technique was developed in conjunction with a health care professionals. Trabecular metal acetabular revision system cupcage construct fig. Surgical management of a long segmental defect of the. Each surgeon should exercise his or her own independent judgment in the diagnosis and.
A novel expandable titanium vertebral body replacement vbr provides enhanced stability following a corpectomy procedure. Cupcage construct surgical technique 3 exposure and acetabular assessment 3 prepare the acetabulum 3 implant the revision shell 3. Class 2 device recall zimmer anatomical shoulder handle. The surgical technique for the cupcage construct has been previously described 15. Surgical technique developed in conjunction with godfrey j.
467 321 94 1129 1098 1092 558 552 1050 379 1520 862 1422 1073 1650 1110 1466 604 518 654 364 34 746 1269 129 1427 1223 7 1421 16 96 1419 1218 1021 686 643 64 597 1323 945